NEC UNIVERGE SV8100 Programming Manual page 277

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Input Data (Continued)
Item
No.
04
05
06
07
Feature Cross Reference
SV8100 Programming Manual
Item
Dial Sending Start Time for SLT or ARS
When ARS or an analog extension user
accesses a trunk and dials an outside call, the
system waits this time before outdialing the
first digit.
When using a third-party external paging
device, set this option to 1. In addition, set
Program 20-03-03 to 1.
SLT Operation Mode
Headset Ringing Start Time (for SLT)
Define the headset ringing start time. After this
time expires from the time when a single line
telephone is off-hook, the system sets the
single line telephone to headset ringing mode.
Trunk Call Dial Forced Sending Start Time
(Forced Dial)
Conditions
None
Single Line Telephones, Analog 500/2500 Sets
Input Data
Default
0~64800 seconds
0 = Normal Mode
1 = Extended
Mode 1
2 = Extended
Mode 2
0~64800 seconds
0~64800 seconds
Issue 11.0
Related
Program
3
20-03-03
0
5
20-13-38
0
20-03-03
20-03-04
2 - 235