Registration Of Standard Sip Terminal - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level:
IN
Description
Use Program 15-24 : Registration of Standard SIP Terminal to register data in the
standard SIP terminal where Register is not used.
(This program requires software revision 4.00 or higher.)
Item
Feature Cross Reference
None
SV8100 Programming Manual
Program 15 : Extension, Basic Setup

15-24 : Registration of Standard SIP Terminal

Item
No.
01
Using IP Address
IP Address of the standard SIP
terminal that is used as the SIP
extension. When Program 15-24-03 is
set to 1, this Program cannot be
changed from 0.0.0.0 (except using
PCProgramming).
02
Call Procedure Port
Call procedure port of the standard
SIP terminal that is used as SIP
extension.
03
Registration Setting when
REGISTER isn't used
Enables or disables the Registration
method. An error will occur if Program
15-24-01 is 0.0.0.0 and this Program
is set to 1 (except using
PCProgramming).
Conditions
None
Input Data
0.0.0.0~255.255.255.255
0~65535
0 = Disable
1 = Enable
Issue 11.0
Default
0.0.0.0
5060
0