Trunk Ring Tone Range; Table 2-8 Program 22-03 - Incoming Signal Frequency Patterns - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level:
IN
Description
Use Program 22-03 : Trunk Ring Tone Range to select the ring tone range for the
trunk. The trunk uses a ring tone in the range selected when it rings an extension.
Eight ring tones are available. Customize the Trunk Ring Tones in Program 82-01.
Input Data
Item
No.
01
Incoming Signal
Frequency Pattern
SV8100 Programming Manual
Program 22 : Incoming Call Setup
Trunk Port Number
Ring Tone Pattern
0~3 = Tone Pattern 1~4
4~8 = Melody 1~5
9~12 = Tone Pattern
5~8
Table 2-8 Program 22-03 – Incoming Signal Frequency Patterns
Type
Pattern 1
High
Middle
Low
Pattern 2
High
Middle
Low
Pattern 3
High
Middle
Low
Pattern 4
High
Middle
Low
Pattern 5
High
Middle
Low

22-03 : Trunk Ring Tone Range

Default
Description
0
Select the ring tone range for the trunk.
The trunk uses a ring tone in the range
selected when it rings an extension.
Eight ring tones are available.
Frequency 1
Frequency 2
1100Hz
1400Hz
660Hz
760Hz
520Hz
660Hz
1100Hz
1400Hz
660Hz
760Hz
520Hz
660Hz
2000Hz
760Hz
1400Hz
660Hz
1100Hz
540Hz
2000Hz
760Hz
1400Hz
660Hz
1100Hz
540Hz
1400Hz
540Hz
760Hz
540Hz
660Hz
540Hz
Issue 11.0
001~200
Related
Program
15-02
Modulation
16Hz
16Hz
16Hz
8Hz
8Hz
8Hz
16Hz
16Hz
16Hz
8Hz
8Hz
8Hz
16Hz
16Hz
16Hz
2 - 341

Hide quick links:

Advertisement

Table of Contents
loading