Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each
T1 Trunk type.
Item
01
02
03
04
05
06
07
08
09
10
11
12
13
2 - 692
Name
Answer Signal Detection Time
(Loop)
Answer Signal Detection Time
(Ground)
Answer Signal Detection Time
(DID)
Answer Signal Detection Time
(E&M)
Answer Signal Detection Time
(OPX)
Clear Signal Detection Time
(Loop)
Clear Signal Detection Time
(Ground)
Clear Signal Detection Time
(DID)
Clear Signal Detection Time
(E&M)
Clear Signal Detection Time
(OPX)
Ringing Signal Detection Time
(Loop)
Ringing Signal Detection Time
(Ground)
Ringing Signal Detection Time
(DID)

81-08 : T1 Trunk Timer Setup

Input Data
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~250
(8ms ~ 2000ms)
1~250
(8ms ~ 2000ms)
1~250
(8ms ~ 2000ms)
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Default
15
60ms
15
60ms
15
60ms
15
60ms
15
60ms
6
600ms
6
600ms
6
600ms
6
600ms
6
600ms
10
80ms
10
80ms
10
80ms

Hide quick links: