Input Data (Continued)
Item
No.
28
29
30
31
32
33
34
SV8100 Programming Manual
Item
RTP TX Level Control
Select transmit level control mode.
RTP TX Voice Level Control
Mode
Effective when 84-31-28 = 1
RTP RX Automatic Level Control
Level
Normally not used. Select target
gain. Effective when 84-31-28 = 2
RTP TX HLC Threshold
Select HLC threshold level.
Effective when 84-31-28 = 3
RTP TX Gain Compression
Mode
Transmit Gain Compression on or
off. Effective when 84-31-28 = 3
RTP TX Gain Compression
Threshold
Transmit Gain Compression on or
off. Effective when 84-31-32 = 1
RTP RX Level Control
Normally not used. Select receive
level control mode.
Input Data
0 = Disable
1 = TX Level Control Mode
2 = TX Automatic Level Control
Mode
3 = TX HLC (high Level)
0~16 (-24 ~ +24)
0 = -24dB
1 = -21dB
:
8 = 0dB
:
15 = 21dB
16 = 24dB
0~12 (-42 ~ -6)
0 = -42dBm
1 = -39dBm
:
7 = -21dBm
:
11 = -9dBm
12 = -6dBm
0~42 (-42 ~ 0)
0 = -42dBm
1 = -41dBm
:
41 = -1dBm
42 = 0dBm
0 = Disable
1 = Enable
0~42 (-42 ~ 0)
0 = -42dBm
1 = -41dBm
:
41 = -1dBm
42 = 0dBm
0 = Disable
1 = RX Level Control Mode
2 = RX Automatic Level Control
Flag
Issue 11.0
Default
0
8
7
42
1
42
0
2 - 815