Ipl Basic Setup - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 11.0
Level:
IN
Description
Use Program 84-26 : IPL Basic Setup to set the IP address of IPL and the port.
Index 1
2 - 800
Program 84 : Hardware Setup for VoIP
Slot Number
VoIP GW Number
Item
Item
No.
01
IP Address
When using a
PZ-XXIPLA assign one
IP address per 16
channels (e.g. a
PZ-32IPLA will require 2
addresses, a PZ-64-
IPLA will require 4
addresses, and a PZ-
128IPLA will require 8
addresses) to each
gateway. When using a
PZ-XXIPLB assign only
one IP address. All
channels will utilize this
one address. With both
the PZ-XXIPLA and the
PZ-XXIPLB assign any
unused gateway's to ip
address 0.0.0.0
02
RTP Port Number
RTP/RTCP port for
GW2~8 are not used by
IPLB.

84-26 : IPL Basic Setup

Input Data
xxx.xxx.xxx.xxx
172.16.0.20~172.16.16.0.27
0~65534
Program 84 : Hardware Setup for VoIP
UNIVERGE SV8100
1
01~08
Default
Slot 1 = 172.16.0.20
:
Slot 4 = 172.16.0.44
VoIP GW Number 1~8:
VoIP GW1 = 10020
VoIP GW2 = 10052
VoIP GW3 = 10084
VoIP GW4 = 10116
VoIP GW5 = 10148
VoIP GW6 = 10180
VoIP GW7 = 10212
VoIP GW8 = 10244