Program 81 : Basic Hardware Setup For Trunk; Cot Initial Data Setup - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Program 81 : Basic Hardware Setup for Trunk

Level:
MF
Description
Use Program 81-01 : COT Initial Data Setup to define the various basic data
parameters for the COT (CO blade) Unit.
Input Data
Item
No.
01
02
03
04
05
06
07
08
09
10
11
12
SV8100 Programming Manual
Item
PCM Encoding Method
Specification
Loop Current Detection Time
Clear Signal (Open Loop)
Detection Time
This is the loop start trunk disconnect
recognition timer.
Ringing Signal Detection Minimum
Time
Single Ringing Detection Minimum
Time
Double Ringing Detection
Minimum Off Time
Double Ringing Detection
Maximum Off Time
Ringing Signal not Detection
Minimum
Time Ringing Signal Stop
Detection Time
Continuous Ringing Minimum
Time
Continuous Ringing Maximum
Time
Caller ID Detection Time

81-01 : COT Initial Data Setup

Input Data
0 = -law
1 = A-law
1~255
(8~2040ms)
1~255
(8~2040ms)
1~255
(8~2040ms)
0~255
(0,8~2040ms)
0~255
(0,8~2040ms)
0~255
(0,8~2040ms)
1~255
(8~2040ms)
1~255
(64~16320ms)
0~255
(0,8~2040ms)
0-255
(0,8~2040ms)
0~255
(0~16320ms)
Program
81
Default
0
75
(600ms)
38
(304ms)
13
(104ms)
82
(656ms)
13
(104ms)
50
(400ms)
88
(704ms)
94
(6016ms)
38
(304ms)
88
(704ms)
0
(0ms)