NEC UNIVERGE SV8100 Programming Manual page 732

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 11.0
Item
Feature Cross Reference
2 - 690
Item
No.
12
T313
Specify the timer value started when
connection request is sent. Valid
range 1 ~ 4 seconds in 1 second
increments. Value of 0 indicates timer
not used.
13
T314
Specify the timer value started when
message segment is received.
14
T316
Specify the timer value started when
RESTART is sent.
15
T317
Specify the timer value started when
RESTART is received.
16
T318
Specify the timer value started when
RES is sent. This timer is valid for
user side use only.
17
T319
Specify the timer value started when
SUSPEND is sent. This timer is valid
for user side use only.
18
T320
Specify the timer value when
B-channel access: connection is
received, or D-channel access:
DL-ESTABLISH confirmation or
indication is received.
19
T321
Specify the timer value started when
STATUS ENQ is received.
20
T322
Specify the timer value upon
D-channel failure.
Conditions
None
ISDN Compatibility
Description
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Input Data
1~254 (sec)
1~254 (sec)
(T317+1)~254 (sec)
1~(T316-1)
1~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
Default
4
4
120
60
4
4
30
30
4

Hide quick links: