Lcd Display - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 11.0
Alarm
Type
Report
No.
93
2
0
NetLink node
connection
detection.
94
2
0
NetLink node
secession
detection.
95
2
0
Data Base
replication
failure.
96
1
0
Data base
recovery fail.
97
2
0
DB recovery
operation
start.
98
2
0
DB recovery
operation
finish.
99
1
0
NetLink
configuration
error.
100
1
0
NetLink link
error.
Feature Cross Reference
None
2 - 848
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
Node connection with
NetLink Primary was
detected.
Secession of the node
detected with NetLink
Primary.
Because Secondary is in
programming mode, the
replication of DB cannot be
executed.
Error happened when
DataBase recovery
operation.
Backup/Restore
Start Data base recovery
operation.
Backup/Restore/Delete
Finish DataBase recovery
operation.
Backup/Restore/Delete
The error occurs when the
system tries to start
NetLink without MEMDB.
This alarm occurs when
the primary system cannot
communicate with
secondary system.
Conditions
The entire terminal that has an Alarm Display setting can be set at PRG90-50-01.
System Alarm Type is shown despite the setting done at 90-10-01. If multiple
Alarm Display Setting is set, only one highest priority alarm will be shown on a

LCD Display.

The priority level (highest -> lowest): Alarm 55 > Alarm 7 > Alarm 5 > Alarm 30 >
Alarm 8 > Alarm 52> Alarm 29 > Free Demo License Period.
Cause
Action
Node connection
No action is necessary.
with NetLink
Primary was
detected.
Secession of the
No action is necessary.
node detected with
NetLink Primary.
Logging in with
Log out from Secondary
Secondary in the
programming mode.
Web Pro or the PC
Pro is possibly the
cause.
Lack of resource
Delete unnecessary file
Memory, protected
and restore open area,
area, recovery data
then try operation
file corruption are
again.
possible reasons
for this.
Start Data base
No action is necessary.
recovery operation.
Finish Data base
No action is necessary.
recovery operation.
Install PZ-ME50 US.
PRG51-01-01 is set
without PZ-ME50
US.
Primary system
Primary system cannot
cannot
communicate with
communicate with
Secondary system
Secondary system
because of Network
because of
error.
Network error.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
INF
INF
WAR
WAR
INF
INF
WAR
WAR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents