Item
Item
No.
16
G.723 Jitter Buffer (max)
17
Jitter Buffer Mode
Setting 2 (Self adjusting-silent
period-is not valid by IPLB. If
this value is set, the system will
operate as Setting 3.
18
VAD Threshold
19
Idle Noise Level
Not used by IPLB.
20
Echo Canceller Mode
Not used by IPLB. Echo
canceller setup is 84-31 for
IPLB.
21
Signal Limiter
Not used by IPLB.
Input Data
0~300ms (Note 1)
1 = Static
2 = Adaptive during
silence
3 = Adaptive
immediate
0~30 = -19dB~+10dB
0
= Adaptec
Threshold
1
= -19dB(-49dBm)
:
20 = 0dB (-30dBm)
:
29 = 9dBm(-21dBm)
30 = 10dBm(-20dBm)
5000~7000
(-5000dBm~
-7000dBm)
0 = Disable
1 = Enable
1 = Mode 0
2 = Mode 1
3 = Mode 2
4 = Mode 3
5 = Mode 4
6 = Mode 5
1. There is no limitation.
2. The limitation is the
maximum.
3. Limitation size
4. It is limiting it.
5. Limitation smallness
6. The limitation is
minimum.
Issue 11.0
Default
120
3
20
7000
1
6