Table 4- 4
Optional motor data
Parameter
Description
p0320
Motor rated magnetizing current / short-circuit
current
p0322
Maximum motor speed
p0341
Motor moment of inertia
p0342
Ratio between the total and motor moment of
inertia
p0344
Motor weight
p0352
Cable resistance (component of the stator
resistance)
p0353
Motor series inductance
Table 4- 5
Equivalent circuit diagram for motor data
Parameter
Description
p0350
Motor stator resistance, cold
p0354
Motor rotor resistance, cold
p0356
Motor stator inductance
p0358
Motor rotor leakage inductance
p0360
Motor magnetizing inductance
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
4.17 Instructions for commissioning induction motors (ASM)
Remark
-
-
-
-
-
Especially for vector control without encoder
(SLVC) this parameter has a significant
influence on the quality of the closed-loop
control at low speeds
This parameter is required for the correct
function of flying restart operating mode.
-
Remark
-
-
-
-
-
Vector control
217