Siemens SINAMICS S120 Function Manual page 953

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table A- 17
New functions, firmware 4.5
No.
SW function
1
Support of new components CU310-2
2
Support of new components, TM150
3
Support of new components S120M
4
Support for high-frequency spindles with pulse frequencies up to 32
kHz (a current controller cycle of 31.25 µs)
5
PROFINET: Support of the PROFIenergy profile
6
PROFINET: Improved usability for Shared Device
7
PROFINET: Smallest selectable send cycle 250 µs
8
PROFINET: Bumpless media redundancy with CU310-2 PN,
CU320-2 PN and CU320-2 with CBE20
9
Ethernet/IP communication extension via CBE20
10
SINAMICS Link: Smallest adjustable send clock 0.5 ms
11
Parameterization of SINAMICS Link connections without POWER ON
12
Write protection
13
Know-how protection
14
PEM encoderless up to n = 0 rpm
15
Decoupling of the pulse frequency from the current controller cycle
only valid for power units in the chassis format
16
Expansion of the number of process data words for infeeds up to 10
words for the send and receive directions
Safety Integrated functions
17
CU310-2 safety functionality via terminals and PROFIsafe
18
Permanent activation of the speed limit and the safe direction of
rotation without PROFIsafe or TM54F
19
Safely Limited Position (SLP)
20
Transfer of the safely limited position via PROFIsafe
21
Variably adjustable SLS limit
22
New PROFIsafe telegrams 31, 901, 902
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
A.2 Availability of SW functions
SERVO
VECTOR HW component
x
x
Refer to Appendix
A1
x
x
-
x
-
-
x
-
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
-
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
x
x
-
Appendix
951

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents