6.28.2
Requirements and addressing
Requirements for the operation of a Web server:
The Web server is available for all CU310-2 and CU320-2 Control Units via the LAN
interface. For Control Units with PROFINET interface, the Web server is also available via
this interface.
Addressing
The individual drives are addressed in the Web server via the IP address. An assignment to
a symbolic name (e.g. "Roller drive 1") can only take place outside the drive using your IT
infrastructure. A cancellation of the symbolic name is not possible.
The IP address can be taken from the CU parameter assignment. Example:
● Integrated Ethernet interface: r8911
● PROFINET interface: r8931
The commissioning tools (STARTER, SCOUT, etc.) can be used to determine and allocate
IP addresses.
Supported Internet browsers
In the current version, the SINAMICS Web server supports large displays such as on usual
PC screens.
Access to the Web server is possible with the following Internet browsers:
● Microsoft Internet Explorer as of Version 7
● Mozilla Firefox as of Version 3.5
● Opera as of Version 10.50
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Basic functions
6.28 Web server
377