Basic information about the drive system
12.5 Inputs/outputs
12.5.1

Digital inputs/outputs

Signal processing using the digital inputs is shown in the function diagrams listed below.
Properties
● The digital inputs are "high active".
● An open input is interpreted as "low".
● Fixed debounce setting
● Availability of the input signal for further interconnection
● Simulation mode settable and parameterizable.
● Isolation block by block, set by jumper.
● Sampling time for digital inputs/outputs can be adjusted (p0799)
Function diagrams (see SINAMICS S120/S150 List Manual)
Control Unit 320-2:
● 2120 Digital inputs, isolated (DI 0 ... DI 3)
● 2121 Digital inputs, isolated (DI 4 ... DI 7)
TB30:
● 9100 Digital inputs, isolated (DI 0 ... DI 3)
TM15:
● 9550 Digital inputs, isolated (DI 0 ... DI 3)
● 9552 Digital inputs, isolated (DI 4 ... DI 7)
TM41:
● 9660 Digital inputs, isolated (DI 0 ... DI 3)
858
Delay time = 1 to 2 current controller cycles (p0115[0])
– Inverted and not inverted as a binector output
– As a connector output
– Jumper open: Isolated.
The digital inputs function only if a reference ground is connected.
– Jumper closed, non-isolated.
The reference potential of the digital inputs is the ground of the Control Unit.
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Drive functions