Siemens SINAMICS S120 Function Manual page 417

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
This function module can be activated via the commissioning wizard.
You can check the current configuration in parameter r0108.17.
Function diagrams (see SINAMICS S120/S150 List Manual)
• 8010
• 8011
• 8013
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Load monitoring
• p2181[0...n]
• p2182[0...n]
• p2183[0...n]
• p2184[0...n]
• p2185[0...n]
...
• p2190[0...n]
• p2192[0...n]
Speed setpoint monitoring
• p2150[0...n]
• p2151[0...n]
• p2161[0...n]
• r2198.4
• r2198.5
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Signals and monitoring functions - Speed messages 1
Signals and monitoring functions - Speed messages 2
Signals and monitoring functions - Load monitoring (r0108.17 = 1)
Load monitoring, response
Load monitoring, speed threshold 1
Load monitoring, speed threshold 2
Load monitoring, speed threshold 3
Load torque monitoring torque threshold 1, upper
Load torque monitoring torque threshold 3, lower
Load monitoring, delay time
Hysteresis speed 3
CI: Speed setpoint for messages
Speed threshold 3
CO/BO: Status word, monitoring 2, |n_set| ≤ p2161
CO/BO: Status word, monitoring 2, n_set < 0
Function modules
7.2 Extended monitoring functions
415