Siemens SINAMICS S120 Function Manual page 886

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic information about the drive system
12.8 Examples of replacing components
Example: Replacing a Motor Module/Power Module with a different power rating
Requirements:
● The replaced power unit has a different power rating
● Vector: Power rating of the Motor Module/Power Module not greater than 4 * motor
Table 12- 13 Example: Replacing a power unit with a different power rating
Action
The component has been successfully replaced.
Replacing motors with SINAMICS Sensor Module Integrated or with DRIVE-CLiQ Sensor Integrated
If a defect has occurred in a motor with integrated DRIVE-CLiQ interface (SINAMICS Sensor
Module Integrated), please contact the Siemens office in your region to arrange for repair.
884
current
Switch off the power supply
Replace the defective
component and connect the
new one
Switch on the power supply
Drive object CU:
p0009 = 1
p9906 = 2
p0009 = 0
p0977 = 1
Drive object component:
p0201 = r0200
p0010 = 0
p0971 = 1
Reaction
Alarm A01420
Device configuration
Component comparison
Completing the configuration
Data backup
Use the code number
Completing commissioning
Data backup
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Remark
For p9906 = 2: Caution
Topology monitoring for all
(!) components has been
significantly reduced so that
if DRIVE-CLiQ lines are
accidentally changed over
this will not be detected.
The new order number is
stored in the RAM of the
Control Unit and has to be
copied to the non-volatile
memory with p0977 = 1 and
p0971 = 1. As an alternative,
STARTER can be used to
backup data with a RAM to
ROM operation.