Deactivating A Warning - Siemens SINUMERIK 840D sl Commissioning Manual

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Configuring alarms
14.2 Creating alarm texts via alarm text files
Opening error file
14.2.10

Deactivating a warning

Generally, alarms/messages are not used without alarm texts. If the alarm text is missing,
the warning "No text available" is output.
To deactivate the warning, add the <ControlFlags> area to your "slaesvcadapconf.xml"
configuration file.
You can copy this area from the original file. The "slaesvcadapconf.xml" file is in the
following directory: /Siemens/sinumerik/hmi/base
Setting
In the <MissingTextWarning type="bool" value="FALSE"/> tag, deactivate/activate the
warning.
Entry
TRUE
FALSE
Example
128
1.
Select the "Commissioning" operating area.
2.
Press the "System data" softkey.
3.
Open the corresponding directory and select the desired file.
4.
Press the "Open" softkey to open the error file.
Meaning
The warning is displayed
The warning is deactivated
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0