Siemens SINUMERIK 840D sl Commissioning Manual page 38

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Creating drive connections
6.2 File "logdrive.ini"
Configuring SMB drive
In the following example, a connection to the computer ef36557c is configured with an SMB
network drive. The softkey with the text "LW_SMB" is located on the 2nd horizontal softkey
bar in position 1. In addition, the user name and the associated password are required.
Connection3=// ef36557c /public
NetDriveType3=smbfs
Username3=test
Password3= Passwd02
SK_Connection3=LW_SMBFS
SoftkeyIndex3=9
In addition, you must set up an account on the Windows computer and release the folder
(//ef36557c/public) for this account:
1. Properties/Release/Authorizations/Add...
2. Properties/Security/Add...
Note
Access to a Novell network is not allowed.
Configuring USB drive
In the following example, the USB plug "X203" is configured. The softkey with the text
"X203" is located on the 2nd horizontal softkey bar in position 2.
Connection4=//TCU/TCU2/X203
SK_Connection4=x203
SoftkeyIndex3=10
32
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
HMI sl (IM9)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents