Configuring alarms
14.1
Configuring alarm and message texts via user interface
You can access the following user-specific text files and enter your own alarm texts via the
user interface of the HMI sl:
Text file
oem_alarms_cycles
oem_alarms_plc
oem_partprogram_messages
Procedure
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
Alarms
Cycle alarm texts
PLC alarm texts
Message texts from the part program
1.
Select the "Startup" operating area.
2.
Press the "HMI" softkey.
3.
Press the "Alarm texts" softkey.
The "Select File" window opens and offers the user-specific text
files.
4.
Select the desired file and press the "OK" softkey.
The text editor opens.
5.
Press the "Paste line" softkey to insert a new line.
- OR
Press the "Delete line" softkey to delete a selected line.
6.
Press the "Search" softkey.
The "Find" window appears.
Enter the desired alarm text in the "Text" field.