Siemens SINUMERIK 840D sl Commissioning Manual page 190

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Service and diagnostics
16.7 PROFIBUS diagnostics
• IP address
• Subnet mask
• DHCP server
• Status of sync. DHCP server
• DNS server 1, DNS server 2
• Gateway
• Note
Modifiable parameters
The following parameters of the company network adapter (X130) can be set by selecting
the "Address type":
● Address type
● IP address
● Subnet mask
● DNS server 1 and 2
● Gateway (applies for system and company network)
Address types
● DHCP
● Manual
References
For additional information about network configuration, please refer to the following
documentation:
SINUMERIK 840D sl, Operator Components and Networking (IM5)
184
Current IP address of the network adapter.
IP address of the network adapter (with address type "DHCP").
– Priority of the synch. DHCP server:
Low, High, Master
– Status of the synch. DHCP server:
Active (current NCU is active in the group of NCUs in the "Synced Server" mode and
assigns the IP addresses); Standby (NCU is not active, but could take over the job of
server if the active server fails)
Domain Name Server
All information that is not available is marked in the relevant table line with a hyphen "-".
The values for the settable parameters IP address, subnet mask, DNS server 1, DNS
server 2 and gateway are defined automatically by the DHCP server, in accordance with
the entry in the basesys.ini.
The values for the settable parameters IP address, subnet mask, DNS server 1, DNS
server 2 and gateway can be specified manually; these are then stored in the basesys.ini.
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
HMI sl (IM9)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents