Data backup

15.6 Creating an archive

15.6
Creating an archive
If you only want to backup specific data, then you can select the desired files directly from
the data tree and generate an archive.
You can display the contents of the selected files (XML, ini, hsp, syf files, programs) in a
preview.
You can display information about the file, such as path, name, date of creation and change,
in a Properties window.
Requirement
The access rights depend on the relevant areas and range from protection level 7 (keyswitch
position 0) to protection level 2 (password: Service).
Storage locations
● On the CompactFlash card under
● All configured logical drives (USB, network drives)
NOTICE
USB FlashDrive
USB FlashDrives are not suitable as persistent memory media.
150
/User/sinumerik/data/archive, or
/OEM/sinumerik/data/archive
Software option
You need the "Additional 256 MB HMI user memory on CF card of NCU"
option in order to store the archives on the CompactFlash card in the "User"
area (User/sinumerik/data/...).