Configuring alarms
14.3 Configuring an alarm log
14.3.1

Create configuration file

Create configuration file with HMI sl
1. Copy the sample configuration file "oem_alarmprot_slaesvcconf.xml" from the
2. Store the file in the directory /OEM/sinumerik/hmi/cfg or /User/sinumerik/hmi/cfg
3. Assign the name "slaesvcconf.xml" to the file.
NOTICE
For the persistent storage, the alarm log is written to the CompactFlash card. The alarm log
is not saved in the default configuration.
Create configuration file on PC
You can also create the configuration file externally on a PC.
Editing a file externally (Page 16)
14.3.2

Complete configuration file

Procedure
1. Open the user-specific file "slaesvcconf.xml" in the editor.
2. Enter the number of events to be output in the <Records type .../> tag. The preset value
3. Enter the mode of the persistent storage in the <DiskCare type="int" value="-1"/> tag.
4. You adapt the filter for the entry type in the <Filter> tag. Please observe the following:
130
/Siemens/sinumerik/hmi/cfg directory.
is 500. The maximum number depends on the memory medium.
The following values are possible:
-1: There is no saving of the alarm log (default setting).
0: Each alarm event triggers an immediate saving of the alarm log.
>0: Rhythm of the log saving in seconds: When there is a change, the log is saved every
n > 0 seconds.
– An alarm event is only entered in the log when it satisfies the filter criterion.
– If several filters are specified in succession, they must be logically ORed.
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0