11.3 Configuring Caps Lock

11.3
Configuring Caps Lock
The CAPSLOCK function ensures that text entered via an external keyboard is always
entered in upper case and not in lower case.
The key behavior is set via a display machine data item.
Setting
MD9009 $MM_KEYBOARD_STATE
0
2
If the machine data is changed, the system must be rebooted.
11.4

Switching EXTCALL off

EXTCALL must be switched off, when in certain configurations two HMIs are connected to
one NCU.
Setting
The processing of NC EXTCALL calls by the HMI can be switched off via a display machine
data item.
MD9106 $MM_SERVE_EXTCALL_PROGRAMS
0
1
78
CAPSLOCK off
CAPSLOCK on (default setting)
The key combination "Ctrl" and Shift is used to switch between upper and lower case.
Switch off call processing
Switch on call processing (default setting)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0