Service and diagnostics
16.7 PROFIBUS diagnostics
16.7.2
Displaying network adapters
The current network adapters (system network X120, company network X130) and their
availability are displayed in the "TCP/IP Diagnostics" window.
System network
On the system network, process data communication and image transmission of the
components are executed with operator software to the display units (TCUs).
A TCU and NCU are connected to the system network via Ethernet interface X120.
Company network
The company network is used, for example, to access the network drives.
An NCU is connected to the company network via Ethernet interface X130.
Availability of the network connections
Network adapter connection
Availability
The availability describes the percentage of faulty packages compared to all the sent and
received packages.
Problems in the company network (e.g. logical drives that cannot be reached, double IP
address, etc.) as well as the settling time during power up can result in fluctuations in the
availability.
182
4.
Press the "Details" softkey.
The "PROFIBUS Diagnostics ... - Details" window is opened.
White
Network cable inserted
Red
Network cable not inserted
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0