3.4.4

Closeport

Description
Syntax:
Alternative names:
Privilege level:
Mode of operation
This command closes a port in the firewall opened previously with the "sc openport"
command. This is only necessary when the port is to be closed manually before the time set
with "sc openport" expires. Otherwise the port is closed automatically when the port service
life expires.
ON parameter is the ID number of the firewall rule output by "sc openport".
3.4.5

Connect

Description
Syntax:
Alternative names:
Privilege level:
This action makes a remote file system on a server available on the controller. This is
enabled by linking the remote file system to a local directory, known as the "MOUNTPOINT".
The files offered by the server are then visible under this directory.
NOTICE
Note that when entering this command, the password appears on the screen in plain text
according to the specified syntax.
For path names, use the slash "/" and not the backslash "\".
NCU Operating System (IM7)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
sc closeport ID
---
service
sc connect [-ro] SERVER:/PATH [MOUNTPOINT]
sc connect [-ro] [-public] //[USERNAME[/DOMAIN]
[%PASSWORD]@]SERVER/SHARE [MOUNTPOINT]
mount
none