Filter properties
A filter consists of the following three elements:
● <Identifier> <Relation> <Value>
The following entries are possible for "<Identifier>":
Entry
AlarmID
SourceID:
SourceURL:
<Attribute name>:
The following entries are possible for "<Relation>":
Entry
EQUAL
NOT
LOWER
HIGHER
The following entries are possible for "<Value>":
Numbers
Character
strings
Examples:
Log all alarms with a ClearInfo not equal to 15, i.e. no part program messages:
<CONFIGURATION>
<Protocol>
<Filters>
</Filters>
</Protocol>
</CONFIGURATION>
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
– Several filters must be combined in series with the keyword AND for an AND
operation.
Note
Each incoming or outgoing event of an alarm or message requires a separate entry,
even when they belong to the same alarm or message.
Acknowledgement events are also contained in the alarm log. You require an entry
even when this is presently not recognizable in the alarm log.
Description
Alarm number
See Table Range of alarms (Page 121)
Arbitrary alarm attribute from the "slaedatabase.xml" file, such as "SEVERITY" or
"CLEARINFO".
Description
Equal to
Not equal to
Less than
Greater than
<Siemens_Filter_01 type="QString" value="CLEARINFO NOT 15" />