18.5
Copying and confirming Safety Integrated data
Copying Safety Integrated data
All the NC machine data relevant for the SI functions is transferred to the corresponding
drive parameters.
The SI machine data or drive parameters to define the encoder mounting arrangement must
be separately entered for the NCK and drive.
Note
Certain drive parameters are not copied.
The data can be saved for all safety axes.
References
Further information is available in the Safety Integrated 840D sl Function Manual
Procedure
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
1.
Select the "Startup" operating area.
2.
Press the menu forward key and the "Safety Integ" softkey.
3.
Press the "General MD" softkey if you want to copy and confirm the
general Safety Integrated machine data.
- OR -
Press the "Axis views" softkey if you want to copy and confirm all
Safety Integrated machine data.
- OR -
18.5 Copying and confirming Safety Integrated data
Safety Integrated
199