2. If only VNC connections to the HMI are displayed, press the "Scan for servers" softkey or
Figure 2-2
3. Start a service shell by using the assigned softkey to select "Session 4". In "Session 5",
4. Log on as a service technician using the user name "manufact" and password
5. Create a new "backup" directory under /tmp on the CF card, which you will then use as
6. Use the command "sc connect" to connect the network drive:
7. Using the command "sc save", create the backup file "backup01".
NCU Operating System (IM7)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
<Shift+F6> to display further connections:
Open service shell
the log console is output.
"SUNRISE".
MOUNTPOINT.
Example: mkdir /tmp/backup
sc connect //username%password@server/share /tmp/backup
Please enter here the user name and the password for the network drive that is to be
connected to.
Choose between –full to save all data on the CF card, or –user, if you only want to save
user data in the directory /user.
Example: sc save –full /tmp/backup/backup01
Backing up and Restoring Data
2.3 Data backup on network drive
17