16.6
Action log
16.6.1
Settings for the action log
In the "Action Log Settings" window you specify whether the operating sequences are to be
logged.
You select which control actions are to be logged. This allows you to recontrust operating
sequences at a later stage.
Settings
Logging on
Alarm status change
Keyboard actions
Channel status change
Window switchover
Writing NCK/PLC data
File access
Function calls in the
NCK (PI services)
Curr. program status
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
Logging is activated or deactivated.
Incoming and outgoing alarms are logged.
All actions on the operator panel front and on an external
keyboard are logged.
NC/PLC states are logged via the information channel status. If
this information can be obtained in a timely manner, in many
cases these states can be used to verify the operation of the
machine control panel.
The form and dialog names (assigned by the programmer) are
logged each time a screenform is opened or closed.
The writing of NCK and PLC variables is logged.
Copying to the NC is logged.
Some program sequences, for example, ASUB, are logged.
Additional information for particular events is activated. For
important alarms that require NC Stop, NC Start, or NC Reset,
actual values and the current block are recorded for example.
The program ascertains which channel and which spindle are
used for the additional information.
Service and diagnostics
16.6 Action log
173