Siemens SINUMERIK 840D sl Commissioning Manual page 35

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

● USB global (TCU)
● Windows network (option)
● Local drive (option)
Procedure
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
– Path
Enter the required start directory of the memory medium here.
– Device
Enter the name of the TCU to which the USB storage device is connected here, e.g.
tcu1. The NCU must already know the TCU name.
The remaining settings are the same as in the "USB local" section.
– Path
Enter the network path for a directory that is available on the network here. This path
must always start with //, e.g. //Server01/Part programs.
– User name and password
Enter the user name and the corresponding password for which the directory is
enabled on the server here. The password is displayed in encoded form as as string of
* characters and is stored in the logdrive.ini file in this format.
– Path
Enter the required directory on the local data carrier here.
1.
Select the "Startup" operating area.
2.
Press the "HMI" and "Log. drive" softkeys.
The "Set Up Drives" window opens.
3.
Select the type, connection, access level and softkey icon, then enter
the path, partition, softkey text, text file and text context.
4.
Press the "OK" softkey.
The drive is configured.
Creating drive connections
6.1 Setting up drives