Restoring System

This section describes the procedure to restore the system after installation of the PSU
backplane.
Mount the cabinet in the rack.
1.
For details, see "6.3.4 Putting cabinet in rack."
2.
Connect all the power cords to the power supply unit.
For details, see "6.3.5 Installing power cord."
Note - In a dual power feed, be sure to connect the power cord to the original position
correctly according to the notes written down before maintenance.
3.
Check that the XSCF STANDBY LED on the operation panel is on.
4.
Switch the mode switch on the operation panel to the Locked mode.
For details, see "2.2.2 Operation panel switches."
5.
Log in to the XSCF shell.
6.
Start the system.
For details, see "6.2 Starting System."
7.
Close the rack door.
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
132