Fujitsu M10 Product Notes page 90

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 7-1
Problems with PCI expansion units and workarounds (continued)
SPARC
RTI No.
M10-1
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
78
SPARC
SPARC
M10-4
M10-4S
Description
x
x
When you install a PCI
expansion unit with PCI hot
plug (PHP), there may be lane
degrade.
x
x
When you install a PCI
expansion unit by PCI hot plug
(PHP), a PCI-Express
correctable error may occur and
cause degradation of the PCI
expansion unit at the next reboot.
x
x
When you install a PCI
expansion unit with PCI hot
plug (PHP), the PCI expansion
unit may not be recognized.
Workaround
When using PHP, execute
cfgadm -c configure instead of
cfgadm -c connect.
If there a fault error message is
output after installing a PCI
expansion unit with PHP,
reinstalled the PCI expansion
unit.
If the PCI expansion unit is not
recognized after installing it
with PHP, reinstall the PCI
expansion unit.