Fujitsu M10 Product Notes page 43

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-3
Problems resolved in versions prior to XCP 2043 (continued)
SPARC
RTI No.
M10-1
RTIF2-121206-
x
001
RTIF2-121219-
002
RTIF2-121219-
x
004
RTIF2-121219-
x
005
RTIF2-121219-
x
006
RTIF2-121219-
x
009
RTIF2-121219-
010
SPARC
SPARC
M10-4
M10-4S
Description
x
x
When starting the domain, the
following error message may
appear.
Msg: PCI Express link
not active
x
Some cabinets may not be
recognized if all power cables
are not connected within four
minutes when connecting the
power cables of the system that
is composed of multiple SPARC
M10-4S cabinets.
x
x
While powering on/off the
power supply interlocking
group, the
showremotepwrmgmt(8)
command may be abnormally
terminated with the following
message.
Controller response
timeout.
x
x
When a component with high
temperature or low temperature
at an air inlet is registered, the
information on the second
faulty component (the second
suspect component) displayed
in the FRU may not be correct.
x
x
Replacement of the power
supply unit (PSU) using the
replacefru(8) command may fail
with Warning:005.
x
x
A fan may be displayed in the
FRU as a faulty component
when the error log "TWI access
error" or "Power-off failure" is
registered with SPARC M10-1.
x
The error log "XSCF hang-up is
detected" may be registered
when the switchscf(8) command
is executed.
Workaround
Ignore this message if the
showhardconf(8) command
recognizes the PCI Express
(PCIe) card.
Make sure not to exceed four
minutes to finish connecting all
the power cables when the
system is composed of multiple
SPARC M10-4S cabinets.
Remove and connect the power
cables of all the cabinets again
when there is a SPARC M10-4S
cabinet that is not recognized.
Execute the
showremotepwrmgmt(8)
command again.
Ignore the information on the
displayed second faulty
component (the second suspect
component).
Execute the replacefru(8)
command again and replace the
PSU.
Replace a PSU backplane when
a fan is displayed as a faulty
component for "TWI access
error" or "Power-off failure".
Ignore this error log.
Chapter 3 Information on Software
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents