Table 3-1
Problems that might occur with XCP 2043 and workarounds (continued)
SPARC
RTI No.
M10-1
RTIF2-130307-
001
RTIF2-130319-
002
RTIF2-130319-
x
003
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
22
SPARC
SPARC
M10-4
M10-4S
Description
x
If any of the SPARC M10-4Ss
specified with the diagxbu(8)
command is unimplemented,
the message "PSB#xx-0 is not
installed." showing the PSB No.
that represents the unimplemented
SPARC M10-4S should appear.
However, the PSB No. of the
SPARC M10-4S which has been
implemented may be
erroneously output.
x
Before power-off of the physical
partition (PPAR) completes in
SPARC M10-4S, if you power
off and then power on the input
power supply of a SPARC
M10-4S or a crossbar box again
and power on the PPAR again,
the PPAR in operation may be
powered off if the master XSCF
is switched with the switchscf
(8) command, firmware update,
or failure.
x
x
If you have the shutdown -i5
command and power-off
command compete for
power-off of the PPAR by
executing the former in the
control domain or the latter
upon the ok prompt while
power-off of the physical
partition (PPAR) is performed
with the poweroff(8) command,
"SCF:PPAR issued power-off
request (PPARID X)" may be
registered many times.
Workaround
There is no effective workaround.
Execute the showhardconf(8)
command to check the status of
the SPARC M10-4S to which the
corresponding PSB No. is
assigned.
The SPARC M10-4S which has
not been implemented is not
displayed with the
showhardconf(8) command.
When the corresponding
SPARC M10-4S is displayed,
read the PSB No. in the message
"PSB#xx-0 is not installed." as
that of the unimplemented
SPARC M10-4S specified when
executing the command.
If you power off the PPAR
before powering off the input
power supply of SPARC
M10-4S or crossbar box, check
that power-off the target PPAR
and SPARC M10-4S is complete,
by using the showboards(8) and
showlogs power commands.
Then, power off the input
power supply of SPARC
M10-4S or crossbar box.
Ignore the registered event log,
because the PPAR has been
normally powered off.

Advertisement