Fujitsu M10 Product Notes page 36

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-1
Problems that might occur with XCP 2043 and workarounds (continued)
SPARC
RTI No.
M10-1
RTIF2-130410-
003
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
24
SPARC
SPARC
M10-4
M10-4S
Description
x
If a physical partition (PPAR) is
powered on in the system that
satisfies all the following
conditions, other PPAR may
also be powered on.
The power supply
interlocking is enabled with
the setremotepwrmgmt(8)
command.
A node is created whose
SubNodeID is not set in a
power supply interlocking
management item.
Multiple PPARs are
configured.
Workaround
When the power supply
interlocking is unnecessary
Disable the power supply
interlocking with the
setremotepwrmgmt -c
disable and then delete the
power supply interlocking
setting with the
clearremotepwrmgmt(8)
command.
When the power supply
interlocking is necessary
If the system has multiple
PPARs, create a management
file of a power supply
interlocking by specifying a
PPAR-ID as a SubNodeID,
and then register the power
supply interlocking setting
with the setremotepwrmgmt
-c config.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents