that does not exist may appear in an error log suspected area. This indicates that
an error was detected on the system board (PSB) while diagnosing. The output
PPAR-ID does not have any meaning.
We recommend to connect the control domain console via the XSCF-LAN port.
When a large amount of data is output by connecting to the control domain
console via a serial port, the data may not be displayed properly.
[SPARC M10-4S]
The time taken for processing a command that displays the system configuration
or status (such as showhardconf(8) command, showboards(8) command, and
showpparstatus(8) command) depends on the number of SPARC M10-4S cabinets
or crossbar boxes that configure the system.
[SPARC M10-4S]
If the system has multiple cabinets, BB#01 or XBBOX#81 cabinet may become the
master XSCF at first.
[SPARC M10-4S]
Depending on the system configuration, it may take time to reboot.
[SPARC M10-4S]
If you add a SPARC M10-4S to the SPARC M10-4S on which XCP 2032 is installed,
update to the latest firmware in advance.
Restrictions
Data input/output using SSH, HTTP, HTTPS, or FTP is not possible with the
following commands:
getflashimage(8), dumpconfig(8), restoreconfig(8), setremotepwrmgmt(8),
getremotepwrmgmt(8), dumpcodactivation(8), restorecodactivation(8), and
snapshot(8).
Use a USB device for data input and output.
However, in the following cases, data can be uploaded and downloaded from the
browser:
no-mem and no-io, which can be set by the -s option of the setpcl(8) command, are
not supported at present.
Alive monitoring between the XSCF and a Hypervisor is not supported. Alive
monitoring between the XSCF and a Hypervisor cannot be enabled/disabled even
by using the setpparmode(8) command.
[SPARC M10-4S]
Suppose that the XSCF was switched while connecting to the control domain
console in the SPARC M10-4S that is composed of more than two cabinets. In that
case, connection to the control domain console may not be established until all the
SPARC M10-4S cabinets have been restarted if an attempt has been made to
reconnect the control domain console to the switched master XSCF.
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
10
Importing XCP by selecting the [menu] tab in XSCF Web, and then selecting the
[XSCF]-[Firmware Update] menu
Saving a log by selecting the [menu] tab in XSCF Web, and then selecting the
[XSCF]-[snapshot] menu