Problems with PCI Expansion Units and Workarounds

Problems with PCI Expansion Units
and Workarounds
The following table shows problems that might occur with PCI expansion units and
workarounds for them.
Table 7-1
Problems with PCI expansion units and workarounds
SPARC
RTI No.
M10-1
SPARC
SPARC
M10-4
M10-4S
Description
x
x
When installing a PCI
expansion unit by PCI hot plug
(PHP), among PCI expansion
unit slots 6, 7, 10 and 11, those
without HBA will have
command execution result
"disconnected" instead of
"empty" for the Oracle Solaris
cfgadm(1M) command.
Although the display is not
appropriate, the slots work
normally if you mount HBA.
This phenomenon does not
occur if you restart the logical
domain after connecting the PCI
expansion unit.
Workaround
This is just a display problem
and does not affect operation.