Table 3-1
Problems that might occur with XCP 2043 and workarounds (continued)
SPARC
RTI No.
M10-1
RTIF2-130305-
018
RTIF2-130305-
x
019
RTIF2-130305-
020
RTIF2-130305-
022
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
20
SPARC
SPARC
M10-4
M10-4S
Description
x
An internal error may occur
when performing "Diagnostic
tests" at the time of selecting
"BB" by the replacefru(8)
command or executing the
testsb(8) command. If you check
the error log at this time, you
can see that " no PSB
available in PPAR " is
registered in "PPAR#30" at the
time when the internal error
occurred.
x
x
Diagnosis continues even when
an error occurred on the
testsb(8) command and timeout
occurs after a two-hour wait.
x
If XSCF panic or hang-up
occurs, an error log showing
that XSCF hang-up is
detected may be notified
many times.
x
The poweron(8) command may
fail with the following message
if an error log showing that
XSCF hang-up is detected was
detected and an "unknown"
system board (PSB) was found
by the showboards(8)
command. The same can be said
for the instruction of power-on
using the XSCF Web, APCS, or
the power supply interlocking.
Not powering on : An
internal error has
occurred. Please
contact your system
administrator.
Workaround
An error occurred in the
applicable SPARC M10-4S and
the system board (PSB) is in an
unavailable state. Check the
error log and replace the
SPARC M10-4S.
Execute the showboards(8)
command in another session
while executing the testsb(8)
command to check the status of
PSB to be diagnosed. An
operation does not work
properly if "Test" is set to other
than "Testing" and "Pwr" is set
to "n." In this case, cancel the
testsb(8) command by pressing
[Ctrl] + [C].
There is no effective workaround.
Ignore the logs with the same
contents that were notified at
the same period of time
considering that they are caused
by the same reason.
There is no effective workaround.
Replace the XSCF of the PSB
which is showed as "unknown"
by the showboards(8) command.