Fujitsu M10 Product Notes page 58

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-4
Problems that might occur in any versions of Oracle Solaris and their workarounds (continue d)
SPARC
CR ID
M10-1
x
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
46
SPARC
SPARC
M10-4
M10-4S
Description
x
x
If an access error is detected
when accessing an internal SAS
disk drive, further access to the
disk may become impossible.
Workaround
Perform settings for
multipathing (MPxIO) on the
internal HDD. If the Enhanced
Support Facility 5.0 or later is
applied, you do not have to
perform the following
operations:
Note - Enhanced Support
Facility (ESF) is not supported
on SPARC M10 systems sold
outside of Japan.
[Setting example]
1. Use the format(1M)
command to check the
product and model of the
HDD which is mounted.
# format
2. Add the internal HDD
information to the
/kernel/drv/scsi_vhci.conf file.
[Setting example of scsi_vhci.
conf file]
For Oracle Solaris 11
scsi-vhci-failover-
override =
"TOSHIBA MBF2600RC",
"f_sym";
For Oracle Solaris 10
device-type-scsi-
options-list =
"TOSHIBA MBF2600RC",
"sym-opt";
sym-opt = 0x1000000;
3. Use the stmsboot(1M)
command to enable MPxIO.
# stmsboot -e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents