Table 3-1
Problems that might occur with XCP 2043 and workarounds
SPARC
RTI No.
M10-1
RTIF2-
x
121113-009
RTIF2-
x
121113-025
RTIF2-
x
121129-003
RTIF2-
121219-008
RTIF2-
121219-011
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
16
SPARC
SPARC
M10-4
M10-4S
Description
x
x
While XSCF is running, process
down, panic or watchdog
timeout occurs, which may
cause XSCF not to be restarted
after XSCF reset.
x
x
When a CPU failure occurs, an
error message showing
degradation or offline on Oracle
Solaris may not be output to
Syslog.
x
x
When you execute the
setsnmpvacm(8) command
specifying createview as the
operand, you cannot set an
access restriction using the OID
mask of MIB.
x
x
The device path of the I/O
device that has been used
changes if a CPU memory unit
(CMU) is added to add two
CPUs when the I/O bus
reconfiguration is enabled in
SPARC M10-4 or SPARC
M10-4S with two CPUs installed.
x
The power of a physical
partition (PPAR) may not be
disconnected if deleteboard -c
unassign is executed to the
system board that belongs to
the PPAR while the power of
the PPAR is being disconnected
using the poweroff(8) command.
Workaround
Confirm that XSCF is
successfully started.
If it is not started, turn off the
power of the physical partition
(PPAR), and then disconnect the
input power supply to the
system and back on again (AC
OFF/ON).
When recycling the power
supply to the system, wait for
30 minutes or more to turn on
the input power supply after
disconnecting.
In case XSCF is not started even
if recycling the input power
supply to the system, replace
the CPU memory unit (CMU).
Use the showlogs(8) command
to check a failure state on XSCF.
There is no effective workaround.
When you execute the
setsnmpvacm(8) command
specifying createview as the
operand, do not use the OID
mask of MIB.
There is no effective workaround.
After executing the poweroff(8)
command, confirm that the
status field of the relevant
PPAR shows Powered Off by
using the showpcl(8) command.
Then, execute the deleteboard
(8) command.