Table 5-1
I/O device paths in SPARC M10-4 cabinet (at initial implementation: a two-CPU) (continued)
Internal LAN#2
Internal LAN#3
Internal USB port (rear: USB1.1)
Internal USB port (rear: USB2.0)
Internal USB port (front: USB1.1/2.0)
PCI#0
PCI#1
PCI#2
PCI#3
PCI#4
PCI#5
PCI#6
PCI#7
PCI#8
PCI#9
PCI#10
I/O device paths at PCI expansion unit side
If the PCI slot on the server to which a link card is connected is PCI#X, the following
device path is created to vvvv and u that are indicated in /pci@vvvv/pci@4/pci@0/
pci@u/****@0 that is the device path of PCI#X shown in Table 5-1.
Table 5-2
I/O device paths at PCI expansion unit side (at initial implementation: a two-CPU)
Device
Device path
PCI expansion unit under PCI#X
PCI#1
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@0/****@0
PCI#2
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@1/****@0
PCI#3
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@8/****@0
PCI#4
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@0/****@0
PCI#5
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@1/****@0
PCI#6
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@10/****@0
PCI#7
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0/pci@11/****@0
PCI#8
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@0/****@0
PCI#9
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@1/****@0
PCI#10
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@10/****@0
PCI#11
/pci@vvvv/pci@4/pci@0/pci@u/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@11/****@0
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
60
/pci@8000/pci@4/pci@0/pci@a/network@0
/pci@8000/pci@4/pci@0/pci@a/network@0,1
/pci@8000/pci@4/pci@0/pci@1/pci@0/usb@4/****@1
/pci@8000/pci@4/pci@0/pci@1/pci@0/usb@4,1/****@1
/pci@8000/pci@4/pci@0/pci@1/pci@0/usb@4,1/hub@2/****@1
/pci@8100/pci@4/pci@0/pci@0/****@0
/pci@8100/pci@4/pci@0/pci@8/****@0
/pci@8100/pci@4/pci@0/pci@9/****@0
/pci@8200/pci@4/pci@0/pci@0/****@0
/pci@8200/pci@4/pci@0/pci@8/****@0
/pci@8200/pci@4/pci@0/pci@9/****@0
/pci@8200/pci@4/pci@0/pci@11/****@0
/pci@8300/pci@4/pci@0/pci@0/****@0
/pci@8300/pci@4/pci@0/pci@8/****@0
/pci@8300/pci@4/pci@0/pci@9/****@0
/pci@8300/pci@4/pci@0/pci@11/****@0