Fujitsu M10 Product Notes page 44

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-3
Problems resolved in versions prior to XCP 2043 (continue d)
SPARC
RTI No.
M10-1
RTIF2-121219-
012
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
32
SPARC
SPARC
M10-4
M10-4S
Description
x
When a SPARC M10-4S cabinet
is replaced using the replacefru
(8) command, replacement of
the SPARC M10-4S cabinet may
fail with "internal error"
displayed.
Workaround
Use the following procedure to
replace a SPARC M10-4S
cabinet by using the replacefru
(8) command.
1. Enter "r" to replace the
cabinet in response to the
message "Do you want to
continue?[r:replace|c:cancel]",
which is displayed after the
replacefru(8) command is
executed.
2. Replace the SPARC M10-4S
cabinet and wait for about 15
minutes after the input power
of the cabinet is turned on.
3. Execute the showlogs event
command to display an event
log.
4. Continue the replacement
using either of the following
methods.
When "XSCF update is
started" is displayed in the
event log, wait until a log
"XSCF update has been
completed" is registered.
When "XCP update has
been completed" is
displayed, enter "f" in
response to "Please
select[f:finish]" and then
continue the replacement
according to the instructions
on the screen.
When "XSCF update is
started" is not displayed in
the event log, enter "f" in
response to "Please
select[f:finish]" and
continue the replacement
according to the instructions
on the screen.