Table 3-3
Problems resolved in versions prior to XCP 2043 (continued)
SPARC
RTI No.
M10-1
RTIF2-121219-
013
RTIF2-121219-
014
RTIF2-121219-
015
RTIF2-121219-
x
016
RTIF2-121219-
017
SPARC
SPARC
M10-4
M10-4S
Description
x
When a SPARC M10-4S cabinet
finds an error indicating that
the XSCF cannot be started, not
only an error log for the SPARC
M10-4S cabinet where the error
occurred but also an error log
regarding a cable connection
error in a cabinet that does not
exist may be registered.
x
When the cold replacement is
performed (a replacement
performed in the state of input
power off) due to an error in
BB#00, the setting information
of the XSCF is deleted.
x
When a SPARC M10-4S cabinet
is removed with the initbb(8)
command, the information on
the removed cabinet remains
without being completely
deleted.
x
x
An internal error may occur if
the prtfru(8) command is
executed while powering on/off
or resetting the physical
partition (PPAR).
x
If a SPARC M10-4S cabinet is
powered off after an error log is
registered because a memory
error occurred in BB#00 or
BB#01, the same error log may
be registered again.
Workaround
Ignore the error log regarding a
cable connection error
registered for a SPARC M10-4S
cabinet that does not exist.
To replace a SPARC M10-4S
cabinet due to an error in BB#00,
use the replacefru(8) command.
To remove a SPARC M10-4S
cabinet, perform the cold
removal (the cabinet is removed
by turning off the input power).
Wait for the power on/off or
reset of the PPAR to complete
and then execute the prtfru(8)
command again.
There is no effective workaround.