Table 3-1
Problems that might occur with XCP 2043 and workarounds (continued)
SPARC
RTI No.
M10-1
RTIF2-130305-
x
003
RTIF2-130305-
004
RTIF2-130305-
005
RTIF2-130305-
x
007
RTIF2-130305-
x
009
RTIF2-130305-
016
SPARC
SPARC
M10-4
M10-4S
Description
x
x
If you reconnect the input
power cable soon after it is
unplugged, the error log of
"PSUs detect 100V and 200V at
AC inputs" indicating that an
error in the configuration of the
input power supply may be
registered.
x
When an XSCF unit of SPARC
M10-4S or crossbar box is
replaced using the replacefru(8)
command, the replacement may
fail with the following message
displayed.
[Warning:010]
An internal error has
occurred.
x
If XSCF panic occurs in a
SPARC M10-4S while
processing the diagnose by the
POST after a physical partition
(PPAR) is powered on in the
system that has more than one
SPARC M10-4S cabinet, then
the power may be disconnected
without continuing the process
of powering on the PPAR.
x
x
FRU registered in the error log
is displayed as "PPAR#30" if the
configuration error of the
system board (PSB) is detected
when executing the testsb(8)
command or diagxbu(8)
command.
x
x
Only up to 128 entries are
displayed if the showsnmp(8)
command is executed after 129
entries or more of trap host IP
addresses are registered using
the setsnmp addtraphost
command or the setsnmp
addv3traphost command.
x
Timeout may occur if the XCP
firmware version of a SPARC
M10-4S or crossbar box is
updated using the flashupdate
-c sync command.
Workaround
There is no effective workaround.
Ignore this error log.
Replace the unit again after the
replacefru(8) command is
completed.
If replacement still fails, stop the
system and then replace the unit.
There is no effective workaround.
Make sure that the XSCF of each
SPARC M10-4S is restarted.
Power on the PPAR again if
they are restarted.
There is no effective workaround.
Maintain the applicable PSB of
SPARC M10 system cabinet.
There is no effective workaround.
If abnormal termination does
not occur when 129 entries or
more of trap host IP addresses
are registered using the
setsnmp(8) command, the IP
addresses are registered
successfully.
Execute the flashupdate(8)
command by specifying the -f
option to reupdate the XCP
firmware for all SPARC M10-4S
or crossbar boxes.
Chapter 3 Information on Software