Fujitsu Eternus web GUI User Manual page 348

For eternus dx90 s2; eternus dx80 s2; eternus dx410 s2; eternus dx440 s2
Table of Contents

Advertisement

Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
2
Specify the name of the port group to be created, select all the ports to be
registered in the port group, and click the [Create] button.
Name
Specify the port group name.
An existing port group name cannot be specified.
The following input conditions apply:
-
1 - 16 alphanumeric characters and symbols (except ", (comma)" and "?")
-
Space
Checkbox to select a port
Select the checkbox of the FCoE port to be registered in an FCoE port group.
→ A confirmation screen appears.
An error screen appears in the following conditions:
When the port group name does not satisfy the input conditions
When the port group name has not been entered
ETERNUS Web GUI User's Guide
Copyright 2011 FUJITSU LIMITED
When a port that has the affinity mode enabled (On) is
selected, ports that have the affinity mode disabled (Off)
cannot be selected.
When a port that has the affinity mode disabled (Off) is
selected, ports that have the affinity mode enabled (On)
cannot be selected.
Up to eight ports can be selected.
348