Chapter 5 Volume Management
5.1 Volume Status
Balancing Process
When "Process" is not "Balancing", a "-" (hyphen) is displayed.
-
-
-
-
-
-
5.1.8

Volume (Pinned Data)

The detailed information of pinned data is displayed.
The following items are displayed in the Main area:
LBA
The location of the pinned data in the volume is displayed using the Logical Block Address
(LBA).
RC
The reason (Reason Code) that created the pinned data is displayed.
SK
The Sense Key (SK) part is displayed from the sense information that is output when the
pinned data is created.
Status
The status of TPV balancing is displayed.
Running normally: Active
Stopped due to an error: Error
Progress
The progress of TPV balancing is displayed.
Work Vol. No
The volume number undergoing TPV balancing is displayed.
Work Vol. Name
The volume name undergoing TPV balancing is displayed.
Error Code
The error code of TPV balancing is displayed when an error occurs.
Elapsed Time
The elapsed time of TPV balancing is displayed.
The displayed time is the elapsed time at the point when this screen is displayed.
ETERNUS Web GUI User's Guide
Copyright 2011 FUJITSU LIMITED
68
P2X0-1090-02ENZ0