Chapter 11 System Management
11.2 Functions in the Action Area for System
6
11.2.7.4
Export Panic Dump
"Panic Dump" is the action of outputting (dump) memory information when an error (panic)
occurs, and also the name of the output information itself. This function exports and saves the
memory information of the Controller Module that is stored in the panic dump data, in a segment
size specified by the user. An exported panic dump can be stored on a floppy disk or hard disk,
or sent by E-mail.
Panic dump is used to analyze the cause of a firmware abnormality or hardware error.
The procedure to export the panic dump is as follows:
Procedure
1
Take care so that the files are not overwritten.
When exporting segmented log files, make sure to export the
segment within five minutes. If five minutes passes before
exporting the next segment, the log export fails. After finishing
saving each segment, save the following segment immediately.
If the [Cancel] button in the [File Download] dialog box is clicked
to cancel the operation, an error may occur in the web browser.
To cancel the operation after the [File Download] dialog box is
displayed, wait at least 10 minutes before clicking the [Cancel]
button or click the [Save] button to complete the operation and
delete the unnecessary file.
Click the [Finish] button to return to the [Display Event Log] screen.
→ Exporting log has been completed.
When exporting of the log has been completed, make sure to export
a panic dump.
This function cannot be used when there is no panic dump to be
exported in the ETERNUS DX Disk storage system.
Up to 64 panic dumps can be stored. When all panic dumps in the
ETERNUS DX Disk storage system have been stored within the last 14
days, a new panic dump cannot be saved. Delete panic dumps
immediately after exporting.
Click [Export Panic Dump] in [Action].
ETERNUS Web GUI User's Guide
Copyright 2011 FUJITSU LIMITED
565
End of procedure
P2X0-1090-02ENZ0