Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
4
9.2.3.10
Configure FCoE Port
This function sets the connection information for the FCoE ports that connect the ETERNUS DX
Disk storage system and the host.
The procedure to set FCoE port parameters is as follows:
Procedure
1
2
Click the [Done] button to return to the [Ports] screen.
When changing port parameters during operation, stop access from the
server that is allocated to the target port. Host access does not need to be
stopped to change the port parameters of newly added CA ports.
For more details on FCoE parameter settings, refer to "User's Guide -
Server Connection-" for each OS type.
Select the FCoE port to set the parameters for (multiple selections can be made)
and click [Configure FCoE Port] in [Action].
Multiple selections can be made for the FCoE ports. To set the same
parameters to multiple ports, set the parameters of the copy source
port and click the [Copy] button. Select the copy destination port and
click the [Copy] button. The parameters can be copied.
To set different parameters to multiple ports, select each target port
and set the parameters.
Set the parameters for all of the selected ports and click the [Set] button.
Port
Select the target port or select the copy source port.
The location options for the selected port are displayed:
-
CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
Transfer Rate (Gbit/s)
Set the transfer speed of the target port.
-
10Gbit/s
Set VLAN ID
Specify "Auto" to enable the automatic setting for the fabric name of the target port.
Specify "Fixed" to enable the fixed setting.
When "Auto" is specified, the fabric name of the connected FCoE switch is
automatically obtained and does not need to be specified.
When "Fixed" is specified, enter the fabric name.
"Auto" should be set for normal operation. When "Fixed" is specified, connection to any
switch other than the specified FCoE switch cannot be performed.
ETERNUS Web GUI User's Guide
Copyright 2011 FUJITSU LIMITED
371
End of procedure