Fujitsu Eternus web GUI User Manual page 552

For eternus dx90 s2; eternus dx80 s2; eternus dx410 s2; eternus dx440 s2
Table of Contents

Advertisement

Chapter 11 System Management
11.2 Functions in the Action Area for System
Rebuild/Copyback w/ redundant
Select whether to notify when rebuilding or copy backing (with redundancy) (*1) is per-
formed. When notifying, select the notification method.
*1:
"Rebuilding to hot spare disk is complete", "Copyback starts" and "Copyback complete"
are equivalent to "Redundancy".
Rebuild/Copyback w/o redundant
Select whether to notify when rebuilding or copy backing (without redundancy) (*1)
occurs for each condition shown below. When notifying, select the notification method.
-
Any Time
Notifies always when rebuilding or copy backing (without redundancy) occurs.
-
when HS<0
Notifies only when rebuilding or copy backing (without redundancy) occurs while
available hot spare disk is "Less than 0".
*1:
"Rebuild to hot spare disk is started", "Rebuild to hot spare disk failed" and "Copyback
failed" are equivalent to "Without redundancy".
Complete rebuild
Select whether to notify when a bad sector (*1) is detected in the hot spare where
rebuilding is completed. When notifying, select the notification method.
*1:
A bad sector is the location information (address and length) where an error such as data
reading error occurs during rebuild, copyback, or redundant copy.
Bad data
Select whether to notify when a bad sector is detected in the drive. When notifying,
select the notification method.
Pinned data
Select whether to notify when the pinned data (*1) is detected. When notifying, select
the notification method.
*1:
"Pinned data" is the data left in the cache due to unsuccessful write-back to the drive from
the cache area.
Not ready
Select whether to notify when the ETERNUS DX Disk storage system is in "Not ready"
status (*1). When notifying, select the notification method.
*1:
"Not ready" is the status in which the ETERNUS DX Disk storage system cannot operate
properly due to a cause such as failures in multiple components.
Remote Path Error
Select whether to notify when an REC path error occurs. When notifying, select the
notification method.
REC Buffer Halt (Path Error)
Select whether to notify when an REC buffer halt caused by REC path error occurs.
When notifying, select the notification method.
REC Buffer Halt (Overload)
Select whether to notify when an REC buffer halt caused by overload occurs. When
notifying, select the notification method.
REC Buffer Halt (Other Error)
Select whether to notify when an REC buffer halt caused by an error occurs. When
notifying, select the notification method.