6.2.13 Sending a Reset Command to the PLC

You can send a reset command to the PLC on the monitoring panel.
Procedure
LCD
Issue 12 (2019-01-15)
The following table describes the steps for sending a reset command to the PLC. The
parameter values in the following figures are for reference only.
Copyright © Huawei Technologies Co., Ltd.
Procedure
6. Choose Running Param. and press
Baud rate is set to 115200 by default,
which provides optimal communications
performance and does not need to be
changed.
When Anti-crosstalk is set to Enable, the
inverters equipped with the PLC STA
module on the SN list can connect to the
network.
When Box-type TF No. and Winding No.
of the PLC CCO are consistently set, the
inverters equipped with the PLC STA
module can be automatically added to the
STA list.
When the PLC CCO is SUN2000
V100R001C72SPC104 or later versions,
you can set Networking. When the
SmartLogger communicates with the
SUN2000 over PLC, set Networking to
Enable (Enable by default). When the
SmartLogger communicates with the
inverter over RS485 only, set Networking
to Disable.
Operation Procedure
1. On the default screen, press
the main menu.
6 User Interface
.
to enter
88